[Maintenance/Troubleshooting] 2-6
2.2 Replacing consumables
2
9 Pull the lever to the right to lock it.
% Carefully return the lever at the front to its original position. If the lever is not returned to its original
position, the Front Cover is not closed.
% If it is difficult to operate the lever, push the lever unit to the back.
10 Close the Front Cover.
2.2.2 Replacing an Imaging Unit
The following example shows how to replace a yellow Imaging Unit.
Be sure to replace an Imaging Unit with an unused product. If an Imaging Unit is replaced with a used one,
the message window may not be cleared.
NOTICE
Do not touch the surface of the OPC drum. Doing so may reduce printing quality.
7CAUTION
- Do not touch the copper terminal of the Imaging Unit. Doing so may lead to static electricity damaging
the product.
1 Check the color of the Imaging Unit to be replaced in the message window of the Control Panel.
Comments to this Manuals