Konica-minolta bizhub PRESS C8000e User Manual Page 118

  • Download
  • Add to my manuals
  • Print
  • Page
    / 123
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 117
IC-601 8-3
8.2 When an Error Message Appears
8
8.2 When an Error Message Appears
The following describes the cause and the solution for [ERROR] that appears during scanning.
No user box is registered
It may be trying to store scanned data in a user box that has not been registered.
Solutions
- Before storing the scanned data in a user box, register the user box in [MACHINE] - [Controller] - [Scan
Setting] - [New User Box Reg.]. For details, refer to page 5-6.
Insufficient space in the controller HDD
There may be no sufficient hard disk space in the image controller. Perform the following steps to check the
remaining amount of the hard disk space in the image controller.
1 Start the Web browser.
2 Input the IP address for the image controller in the URL field and press [Enter].
The PageScope Web Connection screen appears.
% For details on "PageScope Web Connection", refer to the User's Guide (POD Administrator's Ref-
erence).
3 Select [Information] - [Option].
4 Check [Printer HDD] - [Remain].
Solutions
- To free up the hard disk space in the image controller, delete the scanned data stored in the hard disk
using the HDD TWAIN driver. For more information, refer to the user's guide for the HDD TWAIN driver.
- You can automatically delete scanned data from a hard disk in the image controller after the elapse of
a certain period of time. You can se the time in [MACHINE] - [Controller] - [Scan Setting] - [Auto Delete
Document]. For details, refer to page 6-41.
Page view 117

Comments to this Manuals

No comments